Crown CTs Series Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
Crown International
1718 W. Mishawaka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
8/06 136318-1J
CTs Series
Multi-channel
Weight (Net, Shipping):
CTs 4200: 27 lb 8 oz (12.5 kg),
32 lb (14.5 kg)
CTs 8200: 36 lb 6 oz (16.5 kg),
47 lb (21.3 kg).
Front Panel Controls and Indicators
Bridge Mode Indicator: Yellow LED, one per chan-
nel pair, illuminates when the channel pair’s Mode
Switch is set to the “Bridge” position. If Mode
switch is changed while amplifi er is powered up,
Bridge LED will fl ash, indicating that the amplifi er
must be powered off and on to reset the Mode.
Ready Indicator: Green LED, one per channel, illu-
minates when the channel is initialized and ready
to produce audio output.
Signal Indicator: Green LED, one per channel, illu-
minates to indicate the presence of input signals
above –40 dBu.
Clip Indicator: Red LED, one per channel, illumi-
nates when the THD of the channel’s output signal
rises to a level typically considered as the onset
of audible clipping. The Clip Indicator also will
illuminate during Thermal Level Control (TLC) or
input overload.
Thermal Indicator: Red LED, one per channel,
ashes when a state of thermal stress or overload
has caused the channel to shut down. If the power
supply goes into thermal overload, all channel
LEDs will fl ash.
Fault Indicator: Red LED, one per channel, fl ashes
when a fault condition has occurred in the channel.
Ventilation Grille: Front-to-rear forced airfl ow.
Data Indicator: Yellow LED indicates IQ Loop data
activity (if the amplifi er is equipped with an IQ-MC
module, and connected to an IQ Loop).
Power Indicator: Blue LED indicates amplifi er has
been turned on and AC power is available. Indica-
tor also fl ashes if the amplifi er shuts off due to an
under-/over-voltage condition on the AC mains.
Power Switch: Amplifi er is on when the switch is
in the IN position.
Back Panel Controls and Connectors
AC Power Cord Connector: IEC inlet, type 320;
100/120VAC units: 15A;
220/230/240VAC units: 10A.
Voltage is indicated above IEC inlet.
Output Connectors: One four-pole terminal strip
for every two channels with touch-proof cover.
Accepts up to 10 AWG terminal forks.
Accessory Panel: CTs 4200 accepts an optional
VCA-MC4A module. CTs 8200 accepts an optional
VCA-MC8 module.
Channel Level Controls: One 21-position detented
rotary potentiometer per channel, ranging from
infi nity (–70 dB) to 0 dB attenuation.
Input Connectors: Removable Phoenix-style bar-
rier connectors for balanced input.
Mode Switch: Used on each consecutive pair
of channels, this four-position switch is used to
select the amplifi er’s mode of operation: Dual 8/4
ohms, Dual 70V, Bridge-Mono 16/8 ohms, and
Bridge-Mono 100V.
Cooling Vents: Front-to-rear forced airfl ow.
Options
Control Modules: VCA-MC4A: VCA module for CTs
4200A. VCA-MC8: VCA module for CTs 8200.
Wall-mount level control panels for use with VCA
module: 1-VCAP: Single-gang panel with 1 VCA
channel volume control. 4-VCAP: Two-gang panel
with 4 VCA channel volume controls.
T-170V: This is an autoformer that allows 100V
output from the amplifi er, and allows other ampli-
ers without direct constant voltage output to be
easily integrated into distributed systems.
TP-170V: This is a rack-mountable panel with four
autoformers as described above.
Protection Systems
Thermal Level Control (TLC): If an amplifi er chan-
nel starts to overheat, the TLC circuit will engage
that channel’s input compressor. By compress-
ing the input, the amplifi er will not generate as
much heat and will have a chance to cool down.
The degree of compression is proportional to the
amount of overheating. If the channel becomes
too hot for safe operation even after full TLC
limiting, the channel will shut off, and the Thermal
Indicator for that channel will fl ash brightly to alert
the user that a state of thermal stress or overload
has cause the channel to shut down.
FIT (Fault Isolation Topology): Isolates faults
within affected channels.
Fault: If an amplifi er channel requires service,
the corresponding Fault indicator will illuminate
to alert the user of this condition. If this occurs,
return the amplifi er to the Crown factory or to an
authorized Crown service center.
High-Pass Filter: A fi xed 35-Hz (70-Hz in CTs
4200) high-pass fi lter per channel pair is auto-
matically inserted when the mode switch is set to
either of the constant-voltage settings. The high-
pass fi lter corner frequency in the CTs 8200 can be
set to 70 Hz, or bypassed, with a service option.
AC Under-/Over-Voltage Protection: If the AC
line voltage varies out of an acceptable range, the
amplifi er’s power supply turns off and the blue
Power LED fl ashes. The amplifi er will turn back on
when the AC line voltage returns to safe operating
levels.
Models
Under-Voltage
Limit
Over-Voltage
Limit
100VAC (CTs
8200 only)
90VAC 110VAC
120 VAC units 108VAC 132VAC
220V/230V/240V
units
198VAC 264VAC
Power Fuse: A fuse protects the amplifi er from
excessive AC current draw.
Inrush Limiting: A soft-start circuit in the power
supply minimizes the amplifi er’s current draw
during power-on.
Variable-speed Fan: Continuously variable speed
fan directs the airfl ow through the amplifi er for
cooling.
Specifi cations subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown, Crown Audio, IQ System and Multi-Mode are
registered trademarks of Crown International. Other trade-
marks are the property of their respective owners.
Printed in U.S.A.
© 2006 Crown Audio
®
, Inc.
Crown’s Three-Year, No-Fault, Fully Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown amplifi er—an
unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown
amplifi er is warranted to meet or exceed original specifi cations for the fi rst three years of ownership.
During this time, if your amplifi er fails, or does not perform to original specifi cations, it will be
repaired or replaced at our expense. About the only things not covered by this warranty are those
losses normally covered by insurance and those caused by intentional abuse. And the coverage is
transferable, should you sell your amplifi er.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
574-294-8200.
Vue de la page 1