Vue de la page 8
5
Front Panel Controls
There are six front panel controls on the FM RTC. These controls are:
Tx1 RF Power Threshold
Tx2 RF Power Threshold
VOX Attack Timeout
VOX Decay Timeout
System Reset
Operator Restart
The following sections detail the operation and use of each of these controls.
System Reset
The System Reset is the only unlabeled control on the FM RTC front panel.
Fault conditions, such as antenna relay switching problems or transmitter lock-outs
require user intervention by resetting the RTC using this control.
Operator Restart
Operator Restart button has the following function on the FM RTC.
Pushing and releasing Operator Restart switches the system between the
primary and secondary transmitters. Switch between transmitters to
exercise the RF antenna relay or verify the operation of the secondary
transmitter.
VOX Timeout Settings
There are two VOX adjustments on the FM RTC which control switching after loss
or return of audio.
VOX Attack Timeout sets the length of time a loss of audio will trigger
switching from the primary to secondary transmitter. The timeout is
adjustable from 3 to 120 seconds.
VOX Decay Timeout sets the time the audio signal must be present before the
FM RTC switches from the secondary to the primary Transmitters. The
timeout is adjustable from 3 seconds to 120 seconds.
Vue de la page 8