Macro-Tech 3600VZ Power Amplifier
Page 20
Fig. 4.2 Macro-Tech Indicator States
when an input signal that is too large begins to cause
early clipping distortion at the input.
Note: the Channel
2 IOC indicator will stay on in Parallel-Mono mode.
4.3 Protection Circuits
Macro-Tech
amplifiers provide extensive protection
and diagnostics capabilities. Protection systems in-
clude
ODEP
, “standby”, and an AC circuit breaker.
These features provide protection under any condi-
tions.
ODEP
SIGNAL
/
IOC
OFF
OFF
There is no power to the amplifier and all indicators are off, including the Enable light.
Possible reasons: (1) The amplifier’s enable switch is off. (2) The amplifier is not plugged into the power
receptacle. (3) The AC circuit breaker has been tripped. (4) The amplifier’s low-voltage power supply
fuse has blown.
Indicator Status Amplifier Condition
ODEP
SIGNAL
/
IOC
ON
OFF
Normal operation for a channel with NO audio output. Possible reasons: (1) There is no input signal.
(2) The input signal level is very low. (3) The channel’s level control is turned down.
ODEP
SIGNAL
/
IOC
ON
Normal
Normal operation for a channel with audio output. The
ODEP
indicator will remain at full intensity
to show that there is reserve thermodynamic energy, and the signal/
IOC
indicator will flash with normal
intensity to show that the channel has audio output.
ODEP
SIGNAL
/
IOC
ON
Bright
The channel’s output is exceeding 0.05% distortion. The input signal level is too high and
IOC
is
reporting an input overload or output clipping.
ODEP
SIGNAL
/
IOC
OFF
Bright
The amplifier channel is in standby mode. Possible reasons: (1) A
P.I.P.
module like an IQ
P.I.P.
has turned off the channel’s high-voltage power supply. (2) The amplifier has just been turned on and
is still in the four second turn-on delay. (3) The DC / low-frequency protection circuitry has been
activated. (4) The fault protection circuitry has been activated. (5) The transformer thermal protection
circuitry has been activated.
ODEP
limiting has been activated. Possible reasons: (1) The amplifier’s air filters are blocked and
need to be cleaned. (2) There is insufficient cooling because of inadequate air flow or air that is too hot.
(3) The load impedance for the channel is too low because the output is shorted or the amplifier is
driving too many loudspeakers for the selected stereo/mono mode. (4) The amplifier channel is
continuously being driven to very high output levels.
ODEP
SIGNAL
/
IOC
OFF
Normal
ODEP
limiting is about to begin. Possible reasons: (1) The amplifier’s air filters are blocked and need
to be cleaned. (2) There is insufficient cooling because of inadequate air flow or air that is too hot.
(3) The load impedance for the channel is too low because the output is shorted or the amplifier is
driving too many loudspeakers for the selected stereo/mono mode. (4) The amplifier channel is
continuously being driven to very high output levels.
OR
OR
OR
Channel 2 only: The amplifier is in Parallel-Mono mode. The Channel 2 signal/
IOC
indicator always
turns on to full brightness whenever the amplifier’s stereo/mono switch is set to Parallel-Mono mode.
A channel’s circuit breaker has tripped. Transformer overload can cause a channel’s circuit
breaker to trip.
4.3.1 Output Device Emulation Protection
(ODEP)
Crown invented
ODEP
to solve two long standing prob-
lems in amplifier design: To prevent amplifier shutdown
during demanding operation and to increase the effi-
ciency of output circuitry.
To do this, Crown established a rigorous program to
measure the
safe operating area
(SOA) of each output
transistor before installing it in an amplifier. Crown also
designed intelligent circuitry to simulate the instanta-
neous operating conditions of those output transistors.