Instructions for Installation of Oil
Furnace Circulating Fan Upgrade Kits
For Furnace Models:
CHB68-112 CHC68-96 CLBF68-112
CLBR68-112
: Failure to follow these instructions exactly may result in a fire or
explosion causing property damage, personal injury or loss of life.
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
What to do if you find an oil leak:
DO NOT try to operate this appliance.
If possible, close the manual fuel shutoff valve on the oil supply tank.
Immediately call your oil supplier. Follow the oil supplier’s instructions.
If you cannot reach your oil supplier, call the fire department.
A qualified installer, service agency, or the oil supplier must perform installation and
service.
These instructions should be:
read prior to installation.
retained for qualified service personnel
reviewed before performing any service or maintenance.
Crown Boiler Company
3633 “I” Street
Philadelphia, Pennsylvania 19134
XX-XXX
ECNXXXX
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - CLBR68-112

Instructions for Installation of Oil Furnace Circulating Fan Upgrade Kits For Furnace Models: CHB68-112 CHC68-96 CLBF68-112 CLBR68-1

Page 2

Only qualified service personnel shall perform installation and service. 1Introduction: These instructions list the steps required to field install

Page 3

Only qualified service personnel shall perform installation and service. 2• On highboy models, this panel will be the lower access panel on the fro

Page 4

Only qualified service personnel shall perform installation and service. 3(Show depiction here of horizontal / counterflow blower compartment, blowe

Page 5

Only qualified service personnel shall perform installation and service. 4B. Install the Upgrade Blower / Motor Assembly ! CAUTION: On horizontal

Page 6

Only qualified service personnel shall perform installation and service. 53. Reconnect the three (3) furnace wiring harness leads to the terminal b